- 16000 Channel %1 block %2 invalid value for lifting direction
- 16005 Channel %1 block %2 invalid value for lifting distance
- 16010 Channel %1 block %2 machining stop after lift fast
- 16015 Channel %1 block %2 wrong axis identifier %3
- 16016 Channel %1 block %2 no retraction position programmed for axis %3
- 16020 Channel %1 repositioning in block %2 is not possible
- 16100 Channel %1 block %2 spindle %3 not available in the channel
- 16105 Channel %1 block %2 spindle %3 cannot be assigned
- 16110 Channel %1 block %2 spindle %3 for dwell time not in control mode
- 16120 Channel %1 block %2 invalid index for tool fine compensation
- 16130 Channel %1 block %2 instruction not allowed with FTOCON
- 16140 Channel %1 block %2 FTOCON not allowed
- 16150 Channel %1 block %2 invalid spindle number with PUTFTOCF
- 16200 Channel %1 block %2 spline and polynominal interpolation not available
- 16300 Channel %1 block %2 denominator polynominal with zero places within parameter range not allowed
- 16400 Channel %1 block %2 positioning axis %3 cannot participate in spline
- 16410 Channel %1 block %2 axis %3 is not a geometry axis
- 16420 Channel %1 block %2 axis %3 programmed repeatedly
- 16421 Channel %1 block %2 angle %3 programmed repeatedly in the block
- 16422 Channel %1 block %2 angle %3 programmed repeatedly in the block
- 16423 Channel %1 block %2 angle %3 programmed repeatedly in the block
- 16424 Channel %1 block %2 coordinate %3 programmed repeatedly in the block
- 16430 Channel %1 block %2 geometry axis %3 cannot traverse as positioning axis in rotated coordinate system
- 16440 Channel %1 block %2 rotation programmed for non-existent geometry axis
- 16500 Channel %1 block %2 chamfer or rounding negative
- 16510 Channel %1 block %2 no facing axis available
- 16700 Channel %1 block %2 axis %3 invalid feed type
- 16710 Channel %1 block %2 axis %3 master spindle not programmed
- 16715 Channel %1 block %2 axis %3 spindle not in standstill
- 16720 Channel %1 block %2 axis %3 thread lead is zero
- 16730 Channel %1 block %2 axis %3 wrong parameter
- 16740 Channel %1 block %2 no geometry axis programmed
- 16750 Channel %1 block %2 axis %3 SPCON not programmed
- 16751 Channel %1 block %2 spindle/axis %3 SPCOF not executable
- 16755 Channel %1 block %2 no stop required
- 16760 Channel %1 block %2 axis %3 S value missing
- 16761 Channel %1 block %2 axis/spindle %3 not programmable in the channel
- 16762 Channel %1 block %2 spindle %3 thread function is active
- 16763 Channel %1 block %2 axis %3 programmed speed is illegal (zero or negative)
- 16770 Channel %1 block %2 axis %3 no measuring system available
- 16771 Channel %1 following axis %2 overlaid movement not enabled
- 16776 Channel %1 block %2 curve table %3 does not exist for axis %4
- 16777 Channel %1 block %2 coupling: following axis %3 for lead axis %4 not available
- 16778 Channel %1 block %2 coupling: Ring coupling at following axis %3 and leading axis %4 impermissible
- 16779 Channel %1 block %2 coupling: too many couplings for axis %3, see active leading axis %4
- 16780 Channel %1 block %2 following spindle/axis missing
- 16781 Channel %1 block %2 master spindle/axis missing
- 16782 Channel %1 block %2 following spindle/axis %3 not available
- 16783 Channel %1 block %2 master spindle/axis %3 not available
- 16785 Channel %1 block %2 identical spindles/axes %3
- 16787 Channel %1 block %2 coupling parameter not changeable
- 16788 Channel %1 block %2 cyclic coupling
- 16789 Channel %1 block %2 multiple link
- 16790 Channel %1 block %2 Parameter is zero or missing
- 16791 Channel %1 block %2 parameter is not relevant
- 16792 Channel %1 block %2 too many couplings for axis/spindle %3
- 16793 Channel %1 block %2 coupling of axis %3 prohibits transformation change
- 16794 Channel %1 block %2 coupling of axis/spindle %3 prohibits reference point approach
- 16795 Channel %1 block %2 string cannot be interpreted
- 16796 Channel %1 block %2 coupling not defined
- 16797 Channel %1 block %2 coupling is active
- 16798 Channel %1 block %2 axis %3 is following axis and prohibits axis container rotation
- 16799 Channel %1 block %2 axis %3 is master axis and prohibits axis container rotation
- 16800 Channel %1 block %2 traverse instruction DC/CDC for axis %3 not allowed
- 16810 Channel %1 block %2 traverse instruction ACP for axis %3 not allowed
- 16820 Channel %1 block %2 traverse instruction ACN for axis %3 not allowed
- 16830 Channel %1 block %2 incorrect position programmed for axis/spindle %3
- 16903 Channel %1 program control: action %2 not allowed in the current state
- 16904 Channel %1 program control: action %2 not allowed in the current state
- 16905 Channel %1 program control: action %2 not allowed
- 16906 Channel %1 program control: action %2 is aborted due to an alarm
- 16907 Channel %1 action %2 only possible in stop state
- 16908 Channel %1 action %2 only possible in reset state or at the block end
- 16909 Channel %1 action %2 not allowed in current mode
- 16911 Channel %1 mode change is not allowed
- 16912 Channel %1 program control: action %2 only possible in reset state
- 16913 Mode group %1 channel %2 mode change: action %3 not allowed
- 16914 Mode group %1 channel %2 mode change: action %3 not allowed
- 16915 Channel %1 action %2 not allowed in the current block
- 16916 Channel %1 repositioning: action %2 not allowed in the current state
- 16918 Channel %1 for action %2 all channels must be in reset state
- 16919 Channel %1 action %2 is not allowed due to a pending alarm
- 16920 Channel %1 action %2 is already active
- 16921 Channel %1 mode group %2 machine data: channel/mode group assignment not allowed or assigned twice
- 16922 Channel %1 subprograms: action %2 maximum nesting depth exceeded
- 16923 Channel %1 program control: action %2 not allowed in the current state
- 16924 Channel %1 caution: program test modifies tool management data
- 16925 Channel %1 program control: action %2 not allowed in the current state, action %3 active
- 16926 Channel %1 channel coordination: action %2 not allowed in block %3, marker %4 is already set
- 16927 Channel %1 action %2 at active interrupt treatment not allowed
- 16928 Channel %1 interrupt treatment: action %2 not possible
- 16930 Channel %1: preceding block and current block %2 must be separated through an executable block
- 16931 Channel %1 subprograms: action %2 maximum nesting depth exceeded
- 16932 Channel %1 conflict when activating user data type %2
- 16933 Channel %1 interrupt treatment: action %2 not allowed in the current state
- 16934 Channel %1 interrupt treatment: action %2 not possible due to stop
- 16935 Channel %1 action %2 not possible due to search run
- 16936 Channel %1 action %2 not possible due to active dry run
- 16937 Channel %1 action %2 not possible due to program test
- 16938 Channel %1 action %2 aborted due to active gear change
- 16939 Channel %1 action %2 rejected due to active gear change
- 16940 Channel %1 action %2 wait for gear change
- 16941 Channel %1 action %2 rejected because no program event has been executed yet
- 16942 Channel %1 start program command action %2 not possible
- 16943 Channel %1 action %2 not possible due to ASUP
- 16944 Channel %1 action %2 not possible due to active search blocks
- 16945 Channel %1 action %2 delayed up to the block end
- 16946 Channel %1 start via START is not allowed
- 16947 Channel %1 start via PLC is not allowed
- 16948 Channel %1 dependent channel %2 still active
- 16949 Correspondence between marker of channel %1 and channel %2 is invalid.
- 16950 Channel %1 search run with hold block
- 16951 Channel %1 search run in a program section that cannot be searched
- 17000 Channel %1 block %2 maximum number of symbols exceeded
- 17001 Channel %1 block %2 no memory left for tool/magazine data
- 17010 Channel %1 block %2 no memory left
- 17020 Channel %1 block %2 illegal array index 1
- 17030 Channel %1 block %2 illegal array index 2
- 17040 Channel %1 block %2 illegal axis index
- 17050 Channel %1 block %2 illegal value
- 17055 Channel %1 block %2 GUD variable not existing
- 17060 Channel %1 block %2 requested data area too large
- 17070 Channel %1 block %2 data is write-protected
- 17080 Channel %1 block %2 %3 value below lower limit
- 17090 Channel %1 block %2 %3 value exceeds upper limit
- 17095 Channel %1 block %2 invalid value
- 17100 Channel %1 block %2 digital input/comparator no. %3 not activated
- 17110 Channel %1 block %2 digital output no. %3 not activated
- 17120 Channel %1 block %2 analog input no. %3 not activated
- 17130 Channel %1 block %2 analog output no. %3 not activated
- 17140 Channel %1 block %2 NCK output %3 is assigned to a function via machine data
- 17150 Channel %1 block %2 maximum of %3 NCK outputs programmable in the block
- 17160 Channel %1 block %2 no tool selected
- 17170 Channel %1 block %2 number of symbols too large
- 17180 Channel %1 block %2 illegal D number
- 17181 Channel %1 block %2 T no.= %3, D no.= %4 not existing
- 17182 Channel %1 block %2 illegal sum correction number
- 17188 Channel %1 D number %2 defined in tool T no. %3 and %4
- 17189 Channel %1 D number %2 of tools defined on magazine/location %3 and %4
- 17190 Channel %1 block %2 illegal T number
- 17191 Channel %1 block %2 T= %3 not existing, program %4
- 17192 TO unit %1 invalid tool designation of ‘%2’, duplo no. %3. No more replacement tools possible in ‘%4’.
- 17193 Channel %1 block %2 the active tool is no longer on toolholder no./spindle no. %3, program %4
- 17194 Channel %1 block %2 no suitable tool found
- 17200 Channel %1 block %2 deleting tool data not possible
- 17202 Channel %1 block %2 deleting magazine data not possible
- 17210 Channel %1 block %2 access to variable not possible
- 17212 Channel %1 tool management: Load manual tool %3, duplo no. %2 onto spindle/ toolholder %4
- 17214 Channel %1 tool management: remove manual tool %3 from spindle/toolholder %2
- 17216 Channel %1 tool management: remove manual tool from spindle/toolholder %4 and load manual tool %3, duplo no. %2
- 17220 Channel %1 block %2 tool not existing
- 17230 Channel %1 block %2 Duplo no. already assigned
- 17240 Channel %1 block %2 illegal tool definition
- 17250 Channel %1 block %2 illegal magazine definition
- 17260 Channel %1 block %2 illegal magazine location definition
- 17262 Channel %1 block %2 illegal tool adapter operation
- 17270 Channel %1 block %2 call-by-reference: illegal variable
- 17500 Channel %1 block %2 axis %3 is not an indexing axis
- 17501 Channel %1 block %2 indexing axis %3 with Hirth tool system is active
- 17502 Channel %1 block %2 indexing axis %3 with Hirth tooth system stop is delayed
- 17503 Channel %1 block %2 indexing axis %3 with Hirth tooth system and axis not referenced
- 17510 Channel %1 block %2 invalid index for indexing axis %3
- 17600 Channel %1 block %2 preset on transformed axis %3 not possible
- 17605 Channel %1 block %2 axis %3 transformation active: inhibits rotation of axis container
- 17610 Channel %1 block %2 axis %3 involved in the transformation, action cannot be carried out
- 17620 Channel %1 block %2 approaching fixed point for transformed axis %3 not possible
- 17630 Channel %1 block %2 referencing for transformed axis %3 not possible
- 17640 Channel %1 block %2 spindle operation for transformed axis %3 not possible
- 17650 Channel %1 block %2 machine axis %3 not programmable
- 17800 Channel %1 block %2 illegally coded position programmed
- 17900 Channel %1 block %2 axis %3 is no machine axis
- 18000 Channel %1 block %2 NCK-specific protection zone %3 wrong. Error code %4
- 18001 Channel %1 block %2 channel-specific protection zone %3 incorrect. Error code %4
- 18002 Channel %1 block %2 NCK protection zone %3 cannot be activated. Error code %4
- 18003 Channel %1 block %2 NCK protection zone %3 cannot be activated.Error code %4
- 18004 Channel %1 block %2 orientation of workpiece-related protection zone %3 does not correspond to the orientation of tool-related protection zone %4
- 18005 Channel %1 block %2 serious error in definition of NCK-specific protection zone %3
- 18006 Channel %1 block %2 serious error in definition of channel-specific protection zone %3
- 18100 Channel %1 block %2 invalid value assigned to FXS[]
- 18101 Channel %1 block %2 invalid value assigned to FXST[]
- 18102 Channel %1 block %2 invalid value assigned to FXSW[]
- 18200 Channel %1 block %2 curve table: block search stop not allowed with definition CTABDEF
- 18201 Channel %1 block %2 curve table: table %3 does not exist
- 18202 Channel %1 block %2 curve table: instruction CTABEND without CTABDEF not allowed
- 18300 Channel %1 block %2 frame: fine shift not possible
- 18310 Channel %1 block %2 frame: illegal rotation
- 18311 Channel %1 block %2 frame: illegal instruction
- 18312 Channel %1 block %2 frame: fine shift not configured
- 18313 Channel %1 block %2 frame: illegal switchover of geometry axes
- 18314 Channel %1 block %2 frame: type conflict
- 18400 Channel %1 block %2 language change not possible:
- 20000 Channel %1 axis %2 reference cam not reached
- 20001 Channel %1 axis %2 no cam signal present
- 20002 Channel %1 axis %2 zero mark not found
- 20003 Channel %1 axis %2 measuring system error
- 20004 Channel %1 axis %2 reference mark missing
- 20005 Channel %1 axis %2 reference point approach aborted
- 20006 Channel %1 axis %2 reference point creep velocity not reached
- 20007 Channel %1 axis %2 reference point approach requires 2 measuring systems
- 20008 Channel %1 axis %2 reference point approach requires second referenced measuring system
- 20050 Channel %1 axis %2 handwheel mode active
- 20051 Channel %1 axis %2 handwheel mode not possible
- 20052 Channel %1 axis %2 already active
- 20053 Channel %1 axis %2 DRF, FTOCON, external zero point offset not possible
- 20054 Channel %1 axis %2 wrong index for indexing axis in JOG mode
- 20055 Channel %1 master spindle not present in JOG mode
- 20056 Channel %1 axis %2 no revolutional feedrate possible. Axis/spindle %3 stationary
- 20057 Channel %1 block %2 revolutional feedrate for axis/spindle %3 is <= zero
- 20058 Channel %1 axis %2 revolutional feedrate: illegal feed source
- 20060 Channel %1 axis %2 cannot be traversed as geometry axis
- 20061 Channel %1 axis %2 cannot be traversed as orientation axis
- 20062 Channel %1 axis %2 already active
- 20063 Channel %1 axis %2 orientation axes cannot be traversed without transformation
- 20065 Channel %1 master spindle not defined for geometry axes in JOG mode
- 20070 Channel %1 axis %2 programmed end position is behind software limit switch %3
- 20071 Channel %1 axis %2 programmed end position is behind working area limit %3
- 20072 Channel %1 axis %2 is not an indexing axis
- 20073 Channel %1 axis %2 cannot be repositioned
- 20074 Channel %1 axis %2 wrong index position
- 20075 Channel %1 axis %2 can currently not oscillate
- 20076 Channel %1 axis %2 oscillating – mode change not possible
- 20077 Channel %1 axis %2 programmed position is behind software limit switch %3
- 20078 Channel %1 axis %2 programmed position is behind working area limit %3
- 20079 Channel %1 axis %2 oscillation path length %3 <= 0
- 20080 Channel %1 axis %2 no handwheel assigned for overlaid motion
- 20085 Channel %1 contour handwheel: traverse direction or overtravel of beginning of block not allowed
- 20090 Axis %1 travel to fixed stop not possible. Check programming and axis data.
- 20091 Axis %1 has not reached fixed stop
- 20092 Axis %1 travel to fixed stop still active
- 20093 Axis %1 standstill monitoring at fixed-stop end point has been triggered
- 20094 Axis %1 function has been aborted
- 20095 Axis %1 illegal torque, current torque %2
- 20096 Axis %1 brake test aborted, additional information %2
- 20100 Channel %1: invalid configuration for digitizing function
- 20101 Communication with the digitizer not possible
- 20102 Channel %1: No or invalid trafo at digitizing active
- 20103 Channel %1: digitizing module does not support 3+2 axis digitizing
- 20105 Channel %1: axes stopped by digitizer. Error code: %2
- 20106 Emergency stop set by the digitizer
- 20108 Invalid data package received from the digitizer. Error codes: %1, %2
- 20109 Error in communication with the digitizer: status code of com-circuit: %1
- 20120 Axis %1: too many compensation relations
- 20121 Axis %1: Configuration error in compensation table %2
- 20122 Compensation table %1: invalid axis assignment
- 20123 Axis %1: different output assignment of multiplied tables
- 20124 Axis %1: sum of compensation values too large
- 20125 Axis %1: change of compensation value is too rapid
- 20130 Channel %1 contour tunnel monitoring
- 20140 Channel %1 motion synchronous action: traversing of command axis %2 see NC alarm %3
- 20141 Channel %1 motion synchronous action: illegal axis type
- 20142 Channel %1 command axis %2: rotation of axis container already enabled
- 20143 Channel %1 axis %2 command axis cannot be started as it is controlled by the PLC
- 20144 Channel %1 block %2 motion synchronous action: system variable access not possible
- 20145 Channel %1 block %2 motion synchronous action: arithmetic error
- 20146 Channel %1 block %2 motion synchronous action: nesting depth exceeded
- 20147 Channel %1 block %2 motion synchronous action: command not executable
- 20148 Channel %1 block %2 motion synchronous action: internal error %3
- 20149 Channel %1 block %2 motion synchronous action: illegal index
- 20150 Channel %1 tool management: PLC terminates interrupted command
- 20160 Channel %1 tool management: PLC can terminate only incorrectly aborted commands
- 20170 Channel %1 machine data $AC_FIFO invalid
- 20200 Channel %1 invalid spindle number %2 with tool fine compensation
- 20201 Channel %1 spindle %2 no tool assigned
- 20203 Channel %1 no active tool
- 20204 Channel %1 PUTFTOC command not allowed with FTOCOF
- 20210 Channel %1 block %3 spindle %2 wrong values for centerless grinding
- 20211 Channel %1 block %3 spindle %2 support point beyond range limits
- 21600 Monitoring for ESR active
- 21610 Channel %1 axis %2 encoder %3 frequency limit exceeded
- 21611 Channel %1 NC-controlled Extended Stop/Retract triggered
- 21612 Channel %1 axis %2 VDI signal ‘Servo enable’ reset during motion
- 21613 Axis %1 measuring system changing
- 21614 Channel %1 axis %2 hardware limit switch %3
- 21615 Channel %1 axis %2 taken from traverse mode to follow-up mode
- 21616 Channel %1 block %2 overlaid motion active at transformation switchover
- 21617 Channel %1 block %2 transformation does not allow to traverse the pole
- 21618 Channel %1 as from block %2 transformation active: overlaid motion too great
- 21619 Channel %1 block %2 transformation active: motion not possible
- 21650 Channel %1 axis %2 overlaid motion not allowed
- 21660 Channel %1 block %2 axis %3 conflict between SYNACT: $AA_OFF and CORROF
- 21665 Channel %1 $AA_TOFF cleared
- 21670 Channel %1 block %2 illegal change of tool direction with $AA_TOFF active
- 21700 Channel %1 block %3 axis %2 touch probe already deflected, edge polarity not possible
- 21701 Channel %1 block %3 axis %2 measurement not possible
- 21702 Channel %1 block %3 axis %2 measurement aborted
- 21703 Channel %1 block %3 axis %2 touch probe not deflected, illegal edge polarity
- 21740 Output value at analog output no. %1 has been limited
- 21750 Error during output of cam signals via timer
- 21760 Channel %1 block %2 too many auxiliary functions programmed
- 21800 Channel %1 workpiece setpoint %2 reached
- 22000 Channel %1 block %3 spindle %2 change of gear stage not possible
- 22010 Channel %1 block %3 spindle %2 actual gear stage differs from requested gear stage
- 22011 Channel %1 block %3 spindle %2 change to programmed gear stage not possible
- 22012 Channel %1 block %2 leading spindle %3 is in simulation.
- 22013 Channel %1 block %2 dependent spindle %3 is in simulation.
- 22014 Channel %1 block %2. The dynamics of leading spindle %3 and dependent spindle %4 is too variably
- 22020 Channel %1 block %3 spindle %2 gear step change position not reached
- 22040 Channel %1 block %3 spindle %2 is not referenced with zero marker
- 22045 Block %2 spindle/axis %3 not available in channel %1 because active in channel %4
- 22050 Channel %1 block %3 spindle %2 no transition from speed control mode to position control mode
- 22051 Channel %1 block %3 spindle %2 reference mark not found
- 22052 Channel %1 block %3 spindle %2 no standstill on block change
- 22053 Channel %1 block %3 spindle %2 reference mode not supported
- 22054 Channel %1 block %3 spindle %2 improper punching signal
- 22055 Channel %1 block %3 spindle %2 configured positioning speed is too high
- 22060 Channel %1 position control expected for axis/spindle %2
- 22062 Channel %1 axis %2 reference point approach: zero marker search velocity (MD) is not reached
- 22064 Channel %1 axis %2 reference point approach: zero marker search velocity (MD) is too high
- 22065 Channel %1 tool management: Tool motion is not possible, as tool %2 with Duplo no. %3 is not in magazine %4
- 22066 Channel %1 tool management: Tool change is not possible, as tool %2 with Duplo no. %3 is not in magazine %4
- 22067 Channel %1 tool management: tool change not possible since there is no tool available in tool group %2
- 22068 Channel %1 block %2 tool management: no tool available in tool group %3
- 22069 Channel %1 block %2 tool management: No tool available in tool group %3, program %4
- 22070 TO unit %1 Please change tool T= %2 into magazine. Repeat data backup
- 22071 TO unit %1 tool %2 duplo no. %3 is active, but not in the magazine area under consideration
- 22100 Channel %1 block %3 spindle %2 chuck speed exceeded
- 22200 Channel %1 spindle %2 axis stopped during tapping
- 22250 Channel %1 spindle %2 axis stopped during thread cutting
- 22260 Channel %1 spindle %2 thread might be damaged
- 22270 Channel %1 block %2 maximum velocity of thread axis at position %3 reached
- 22275 Channel %1 block %2 zero velocity of thread axis at position %3 reached
- 22280 Channel %1 in block %2: Prog. acceleration path too short %3, %4 required
- 22320 Channel %1 block %2 PUTFTOCF command could not be transferred
- 22321 Channel %1 axis %2 PRESET not allowed during traverse motion
- 22322 Channel %1 axis %2 PRESET: illegal value
- 25000 Axis %1 hardware fault of active encoder
- 25001 Axis %1 hardware fault of passive encoder
- 25010 Axis %1 pollution of measuring system
- 25011 Axis %1 pollution of passive encoder
- 25020 Axis %1 zero mark monitoring of active encoder
- 25021 Axis %1 zero mark monitoring of passive encoder
- 25022 Axis %1 encoder %2 warning %3
- 25030 Axis %1 actual velocity alarm limit
- 25031 Axis %1 actual velocity warning limit
- 25040 Axis %1 standstill monitoring
- 25042 Axis %1 standstill monitoring during torque/force limitation
- 25050 Axis %1 contour monitoring
- 25060 Axis %1 speed setpoint limitation
- 25070 Axis %1 drift value too large
- 25080 Axis %1 positioning monitoring
- 25100 Axis %1 measuring system switchover not possible
- 25105 Axis %1 measuring systems differ considerably
- 25110 Axis %1 selected encoder not available
- 25200 Axis %1 requested set of parameters invalid
- 25201 Axis %1 drive fault
- 25202 Axis %1 waiting for drive
- 26000 Axis %1 clamping monitoring
- 26001 Axis %1 parameterization error: friction compensation
- 26002 Axis %1 encoder %2 parameterization error: number of encoder marks
- 26003 Axis %1 parameterization error: lead screw pitch
- 26004 Axis %1 encoder %2 parameterization error: grid point distance with linear encoders
- 26005 Axis %1 parameterization error: output rating
- 26006 Axis %1 encoder %2 encoder type/output type %3 not possible
- 26007 Axis %1 QEC: invalid coarse step size
- 26008 Axis %1 QEC: invalid fine step size
- 26009 Axis %1 QEC: memory overflow
- 26010 Axis %1 QEC: invalid acceleration characteristic
- 26011 Axis %1 QEC: invalid measuring periods
- 26012 Axis %1 QEC: feed forward control not active
- 26014 Axis %1 machine data %2 invalid value
- 26015 Axis %1 machine data %2[%3] invalid value
- 26016 Axis %1 machine data %2 invalid value
- 26017 Axis %1 machine data %2[%3] invalid value
- 26018 Axis %1 setpoint output drive %2 used more than once
- 26019 Axis %1 encoder %2 measurement not possible with this controller module
- 26020 Axis %1 encoder %2 hardware fault %3 during encoder initialization
- 26022 Axis %1 encoder %2 measurement with simulated encoder not possible
- 26024 Axis %1 machine data %2 value changed
- 26025 Axis %1 machine data %2[%3] value changed
- 26030 Axis %1 encoder %2 absolute position lost
- 26031 Axis %1 configuration error master-slave
- 26032 Axis %1 master-slave not configured
- 26050 Axis %1 parameter set change from %2 to %3 not possible
- 26051 Channel %1 in block %2 unanticipated stop crossed in continuous path mode
- 26052 Channel %1 in block %2: path velocity too high for auxiliary function output
- 26070 Channel %1 axis %2 cannot be controlled by the PLC, max. number exceeded
- 26072 Channel %1 axis %2 cannot be controlled by the PLC
- 26074 Channel %1 switching off PLC control of axis %2 not allowed in the current state
- 26080 Channel %1 retraction position of axis %2 not programmed or invalid
- 26081 Channel %1 axis trigger of axis %2 was activated, but axis is not PLC- controlled
- 26100 Axis %1 drive %2 sign of life missing
- 26101 Axis %1 drive %2 communication failure
- 26102 Axis %1 drive %2 sign of life missing
- 26105 Drive of axis %1 not found
- 26106 Encoder %2 of axis %1 not found
- 26110 Independent drive stop/retract triggered
- 27000 Axis %1 is not safely referenced
- 27001 Axis %1 error in a monitoring channel, code %2, values: NCK %3, drive %4
- 27002 Axis %1 test stop is running
- 27003 Checksum error found: %1 %2
- 27004 Axis %1, difference safe input %2, NCK %3, drive %4
- 27005 Axis %1 error in data cross check: static actual value difference
- 27006 Axis %1 Test ext. pulse deletion running
- 27007 Axis %1 acceptance test mode is active
- 27008 Axis %1 SW limit switch deactivated
- 27010 Axis %1 tolerance for safe standstill exceeded
- 27011 Axis %1 safe velocity exceeded
- 27012 Axis %1 safe end position exceeded
- 27013 Axis %1 safe braking ramp exceeded
- 27020 Axis %1 stop E triggered
- 27021 Axis %1 stop D triggered
- 27022 Axis %1 stop C triggered
- 27023 Axis %1 stop B triggered
- 27024 Axis %1 stop A triggered
- 27030 Axis %1 function not supported on this 611D module
- 27031 Axis %1 limit value for safe velocity %2 at gear ratio %3 too large (max. %4)
- 27032 Axis %1 checksum error of safe monitoring. Confirmation and re-test required!
- 27033 Axis %1 parameterization of MD %2[%3] invalid
- 27034 Parameterization of MD %1 invalid
- 27090 Error in data cross check NCK-PLC, %1[%2], NCK: %3; %4 ALSI
- 27091 Error in data cross check NCK PLC, stop of %1
- 27092 Communication broken off during NCK PLC data cross check, error detected by %1
- 27093 Checksum error NCK-SPL, %1, %2, %3
- 27094 Write access to system variable %1 only allowed from NCK-SPL
- 27095 %1 SPL protection not activated
- 27096 SPL start not allowed
- 27100 At least one axis is not safely referenced
- 27101 Axis %1 difference in function safe operational stop, NCK: %2 drive: %3
- 27102 Axis %1 difference in function safe velocity %2, NCK: %3 drive: %4
- 27103 Axis %1 difference in function safe limit position %2, NCK: %3 drive: %4
- 27104 Axis %1 difference in function safe cam plus %2, NCK: %3 drive: %4
- 27105 Axis %1 difference in function safe cam minus %2, NCK: %3 drive: %4
- 27106 Axis %1 difference in function safe velocity nx, NCK: %2 drive: %3
- 27107 Axis %1 difference in function cam modulo monitoring, NCK: %2 drive: %3
- 27124 Stop A triggered at least in 1 axis
- 27200 PROFIsafe: cycle time %1 [ms] too long
- 27201 PROFIsafe: MD %1[%2]: bus segment %3 error
- 27202 PROFIsafe: MD %1[%2]: address %3 error
- 27203 PROFIsafe: MD %1[%2]: SPL assignment error
- 27204 PROFIsafe: double assignment MD %1[%2] – MD %3[%4]
- 27220 PROFIsafe: Number of NCK F modules (%1) <> number of DP modules (%2)
- 27221 PROFIsafe: NCK F module MD %1[%2] unknown
- 27222 PROFI safe: S7 F module PROFI safe address %1 unknown
- 27223 PROFIsafe: NCK F module MD %1[%2] is not a %3 module
- 27224 PROFIsafe: F module MD %1[%2] – MD %3[%4]: double assignment of PROFIsafe address
- 27225 PROFIsafe: slave %1, configuration error %2
- 27240 PROFIsafe: DP M not running up, DP info: %1
- 27241 PROFIsafe: DP M version different, NCK: %1, PLC: %2
- 27242 PROFIsafe: F module %1, %2 faulty
- 27250 PROFIsafe: configuration in DP M changed; error code %1 – %2
- 27251 PROFIsafe: F module %1, %2 reports error %3
- 27252 PROFIsafe: Slave %1, sign-of-life error
- 27253 PROFIsafe: communication fault F master component %1, error %2
- 27254 PROFIsafe: F module %1, error on channel %2; %3
- 27255 PROFIsafe: F module %1, general error
- 27256 PROFIsafe: Current cycle time %1 [ms] > parameterized cycle time
- 27299 PROFIsafe: Diagnosis %1 %2 %3 %4
- 28000 NCU link connection to all other NCUs of the link network has been aborted
- 28001 NCU link connection to the NCU %1 of the link network has been aborted
- 28002 Error on activation of machine data, NCU network-wide machine data were modified by NCU %1
- 28004 NCU link: NCU %1 of the link network is not on the bus
- 28005 NCU link: NCU %1 of the link network not running synchronously
- 28007 NCU link: conflict in configuration data of NCU %1
- 28008 NCU link: conflict in timer setting of NCU %1
- 28009 NCU link: conflict in bus parameters of NCU %1
- 28010 NCU link: the NCU %1 has not received a message
- 28011 IPO time insufficient for NCU link. Link cycle time: %1
- 28012 NCU link: synchronization cycle signal failure %1 times
- 28020 NCU link: too many link axes configured %1
- 28030 Serious alarm on NCU %1, axes in follow-up mode
- 28031 Serious alarm on NCU %1 not yet acknowledged, axes still in follow-up mode
- 28032 Emergency stop activated on NCU %1, axes in follow-up mode
- 28033 Emergency stop on NCU % 1, axes still in follow-up mode
- 29033 Channel %1 axis change of axis %2 not possible, PLC axis movement not yet completed
- 60000 Channel %1 block %2:
- 61000 Channel %1 block %2 no tool compensation active
- 61001 Channel %1 block %2 thread lead incorrect
- 61002 Channel %1 block %2 machining type wrongly defined
- 61003 Channel %1 block %2 no feed programmed in the cycle
- 61004 Channel %1 block %2 configuration geometry axis incorrect
- 61005 Channel %1 block %2 3rd geometry axis not present
- 61006 Channel %1 block %2 tool radius too large
- 61007 Channel %1 block %2 tool radius too small
- 61009 Channel %1 block %2 active tool number = 0
- 61010 Channel %1 block %2 finishing allowance too large
- 61011 Channel %1 block %2 scaling not allowed
- 61012 Channel %1 block %2 different scaling on the plane
- 61013 Channel %1 block %2 basic settings were changed, program cannot be executed
- 61101 Channel %1 block %2 reference plane incorrectly defined
- 61102 Channel %1 block %2 no spindle direction programmed
- 61103 Channel %1 block %2 number of drillings is zero
- 61104 Channel %1 block %2 contour violation of slots/long holes
- 61105 Channel %1 block %2 cutter radius too large
- 61106 Channel %1 block %2 number or distance of circular elements
- 61107 Channel %1 block %2 first drilling depth incorrectly defined
- 61108 Channel %1 block %2 illegal values for parameters _RAD1 and _DP1
- 61109 Channel %1 block %2 parameter _CDIR incorrectly defined
- 61110 Channel %1 block %2 finishing allowance at the base > depth infeed
- 61111 Channel %1 block %2 infeed width > tool diameter
- 61112 Channel %1 block %2 tool radius negative
- 61113 Channel %1 block %2 parameter _CRAD for corner radius too large
- 61114 Channel %1 block %2 machining direction G41/G42 incorrectly defined
- 61115 Channel %1 block %2 approach or retract mode (straight line/circle/plane/space) incorrectly defined
- 61116 Channel %1 block %2 approach or retraction path = 0
- 61117 Channel %1 block %2 active tool radius <= 0
- 61118 Channel %1 block %2 length or width = 0
- 61119 Channel %1 block %2 nominal or core diameter incorrectly programmed
- 61120 Channel %1 block %2 internal/external thread type not defined
- 61121 Channel %1 block %2 number of teeth per cutting edge missing
- 61122 Channel %1 block %2 safety clearance on the plane incorrectly defined
- 61124 Channel %1 block %2 infeed width is not programmed
- 61125 Channel %1 block %2 technology selection in parameter _TECHNO incorrectly defined
- 61126 Channel %1 block %2 thread length too short
- 61127 Channel %1 block %2 transmission ratio of tapping axis incorrectly defined (machine data)
- 61128 Channel %1 block %2 dipping angle = 0 for dipping with oscillation or helix
- 61180 Channel %1 block %2 no name assigned to swivel data block, although MD $MN_MM_NUM_TOOL_CARRIER > 1
- 61181 Channel %1 block %2 NCK software version unsufficient (missing TOOLCARRIER functionality)
- 61182 Channel %1 block %2 name of swivel data block unknown
- 61183 Channel %1 block %2 retraction mode GUD7 _TC_FR beyond value range 0… 2
- 61184 Channel %1 block %2 no solution possible with current input angle values
- 61185 Channel %1 block %2 no or incorrect (min > max) rotary axis angle ranges assigned
- 61186 Channel %1 block %2 rotary axis vectors invalid –> Check installation and start-up of the swivel cycle CYCLE800
- 61188 Channel %1 block %2 no axis name for the 1st axis assigned -> Check installation and start-up of the swivel cycle CYCLE800
- 61200 Channel %1 block %2 too many elements in the machining block
- 61201 Channel %1 block %2 wrong sequence in the machining block
- 61202 Channel %1 block %2 no technology cycle
- 61203 Channel %1 block %2 no positioning cycle
- 61204 Channel %1 block %2 unknown technology cycle
- 61205 Channel %1 block %2 unknown positioning cycle
- 61210 Channel %1 block %2 block search element not found
- 61211 Channel %1 block %2 absolute reference missing
- 61212 Channel %1 block %2 wrong tool type
- 61213 Channel %1 block %2 circle radius too small
- 61214 Channel %1 block %2 no lead programmed
- 61215 Channel %1 block %2 raw dimension incorrectly programmed
- 61216 Channel %1 block %2 feed/tooth only possible with milling tools
- 61217 Channel %1 block %2 cutting speed for tool radius 0 programmed
- 61218 Channel %1 block %2 feed/tooth programmed, but number of teeth is zero
- 61222 Channel %1 block %2 plane infeed greater than the tool diameter
- 61223 Channel %1 block %2 approach path too short
- 61224 Channel %1 block %2 retract path too short
- 61225 Channel %1 block %2 swivel data block unknown
- 61226 Channel %1 block %2 swivel head cannot be exchanged
- 61230 Channel %1 block %2 tool probe diameter too small
- 61231 Channel %1 block %2 ShopMill program %3 cannot be executed, as it has not been tested by ShopMill
- 61232 Channel %1 block %2 loading of magazine tool not possible
- 61233 Channel %1 block %2: Thread inclination incorrectly defined
- 61234 Channel %1 block %2 ShopMill subroutine %4 cannot be executed, as it has not been tested by ShopMill
- 61235 Channel %1 block %2: ShopTurn program %4 cannot be executed, as it has not been tested by ShopTurn.
- 61236 Channel %1 block %2: ShopTurn subroutine %4 cannot be executed, as it has not been tested by ShopTurn.
- 61237 Channel %1 block %2: Retraction direction unknown. Manually retract tool!
- 61238 Channel %1 block %2: Machining direction unknown.
- 61239 Channel %1 block %2: Tool change point lies in the retraction area!
- 61240 Channel %1 block %2: Wrong feed type
- 61241 Channel %1 block %2: No retraction plane defined for this machining direction.
- 61242 Channel %1 block %2: Wrong machining direction
- 61243 Channel %1 block %2: Correct tool change point, tool tip is in retraction area!
- 61244 Channel %1 block %2: Thread lead change results in an undefined thread
- 61246 Channel %1 block %2: Safety clearance too small
- 61247 Channel %1 block %2: Blank radius too small
- 61248 Channel %1 block %2: Infeed too small
- 61249 Channel %1 block %2: Number of edges too small
- 61250 Channel %1 block %2: Key width/Edge length too small
- 61251 Channel %1 block %2: Key width/Edge length too large
- 61252 Channel %1 block %2: Chamfer/Radius too large
- 61253 Channel %1 block %2: No finishing allowance programmed
- 61254 Channel %1 block %2: Error when traversing to fixed stop
- 61255 Channel %1 block %2: Cut-off error: Tool breakage?
- 61301 Channel %1 block %2 measuring probe does not switch
- 61302 Channel %1 block %2 measuring probe collision
- 61303 Channel %1 block %2 safe area exceeded
- 61308 Channel %1 block %2 check measuring distance 2a
- 61309 Channel %1 block %2 check measuring probe type
- 61310 Channel %1 block %2 scale factor is active
- 61311 Channel %1 block %2 no D number is active
- 61316 Channel %1 block %2 center point and radius cannot be determined.
- 61332 Channel %1 block %2 change tool tip position
- 61338 Channel %1 block %2 positioning velocity is zero
- 61601 Channel %1 block %2 finished-part diameter too small
- 61602 Channel %1 block %2 tool width incorrectly defined
- 61603 Channel %1 block %2 groove form incorrectly defined
- 61604 Channel %1 block %2 active tool violates programmed contour
- 61605 Channel %1 block %2 contour incorrectly programmed
- 61606 Channel %1 block %2 contour processing error
- 61607 Channel %1 block %2 starting point incorrectly programmed
- 61608 Channel %1 block %2 wrong cutting edge position programmed
- 61609 Channel %1 block %2 form incorrectly defined
- 61610 Channel %1 block %2 no infeed depth programmed
- 61611 Channel %1 block %2 no intersection point found
- 61612 Channel %1 block %2 thread axis cutting not possible
- 61613 Channel %1 block %2 undercut position incorrectly defined
- 61800 Channel %1 block %2: External CNC system missing
- 61801 Channel %1 block %2: Wrong G code selected
- 61802 Channel %1 block %2: Wrong axis type
- 61803 Channel %1 block %2 programmed axis not present
- 61804 Channel %1 block %2: Progr. position exceeds reference point
- 61805 Channel %1 block %2: The value is absolutely and incrementally programmed
- 61806 Channel %1 block %2: Incorrect axis assignment
- 61807 Channel %1 block %2 wrong spindle direction programmed (active)
- 61808 Channel %1 block %2: The final drilling depth or individual drilling depth is missing
- 61809 Channel %1 block %2: Impermissible drilling position
- 61810 Channel %1 block %2: ISO-G code not possible
- 61811 Channel %1 block %2: Impermissible ISO axis name
- 61812 Channel %1 block %2: Value(s) in the external cycle call incorrectly defined
- 61813 Channel %1 block %2: GUD value incorrectly defined
- 61814 Channel %1 block %2: Polar coordinates not possible with cycle
- 61815 Channel %1 block %2: G40 not active
- 61816 Channel %1 block %2: axes are not at the reference point
- 61817 Channel %1 block %2: The axis coordinates are within the protection zone
- 61818 Channel %1 block %2: The axis area limit values are identical
- 62000 Channel %1 block %2:
- 62100 Channel %1 block %2 no drilling cycle active
- 62101 Channel %1 block %2: Incorrect cutting direction – G3 is generated
- 62103 Channel %1 block %2: The finishing allowance is not programmed
- 62105 Channel %1 block %2 number of columns or lines is zero
- 62180 Channel %1 block %2 no name assigned to swivel data block although machine data $MN_MM_NUM_TOOL_CARRIER > 1
- 62181 Channel %1 block %2 NCK software version unsufficient (missing TOOLCARRIER functionality)
- 62182 Channel %1 block %2: Load swivel head
- 62183 Channel %1 block %2 retraction mode GUD7 _TC_FR beyond value range 0…2
- 62184 Channel %1 block %2 no solution possible with current input angle values
- 62185 Channel %1 block %2 no end stop assigned to rotary axes
- 62186 Channel %1 block %2 illegal rotary axis vectors
- 62187 Channel %1 block %2 name of swivel data block unknown
- 62200 Channel %1 block %2: Start spindle
- 63000 Channel %1 block %2:
- 65000 Channel %1 block %2:
- 66000 Channel %1 block %2:
- 67000 Channel %1 block %2:
- 68000 Channel %1 block %2:
- 70000 Compile cycle alarm
- 75000 OEM alarm
- 75005 Channel %1 block %2 CLC: General programming error
- 75010 Channel %1 block %2 CLC_LIM value exceeds MD limit
- 75015 Channel %1 block %2 CLC(0) with active TOC
- 75016 Channel %1 block %2 CLC: orientation changed for TRAFOOF
- 75020 Channel %1 CLC position offset at lower limit %2
- 75021 Channel %1 CLC position offset at upper limit %2
- 75025 Channel %1 CLC stopped because sensor head has been touched
- 75050 Channel %1 wrong MD configuration, error code %2
- 75051 Channel %1 CC_COPON CC_COPOFF error code %2
- 75060 Channel %1 tolerance window exceeded axis %2
- 75061 Channel %1 coupling active axis %2
- 75062 Channel %1 axes not in standstill axis %2
- 75070 Channel %1 wrong machine data for collision protection %2
- 75071 Channel %1 collision monitoring axis %2
- 75100 Too many analog axes configured
- 75110 Axis %1 reached drift limit
- 75200 Channel %1 wrong MD configuration, %2 incorrect
- 75210 Channel %1 number of axes/axis assignment inconsistent
- 75250 Channel %1 tool parameters incorrect
- 75255 Channel %1 working area error
- 75260 Channel %1 block %2 tool parameters incorrect
- 75265 Channel %1 block %2 working area error
- 75270 Channel %1 tool parameters incorrect
- 75275 Channel %1 block %2 working area error
- 75451 Error with definition of setpoint switchover
- 75452 Axis %1 setpoint switchover not possible in the current state
- 75500 Channel %1 wrong configuration
- 75600 Channel %1 retrace support: wrong MD configuration. Error code %2
- 75601 Channel %1 block %2 invalid parameter in CC_PREPRE()
- 75605 Channel %1 retrace support: internal error, error code %2
- 75606 Channel %1 retraceable contour was shortened
- 75607 Channel %1 resynchronisation not possible