Sinumerik Alarm 300605 Axis %1 drive %2 motor change not valid


Sinumerik Alarm 300605 Axis %1 drive %2 motor change not valid

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
An attempt was made to switch over to a motor data record that is not parameterized.

Reactions:
– Mode group not ready.
– Channel not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.
Remedy:
Parameterize the motor data record selected or switch over to another motor.

Program Continuation:
Clear alarm with the RESET key in all channels of this mode group. Restart part program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 300605 Axis %1 drive %2 motor change not valid