Sinumerik Alarm 300606 Axis %1 drive %2 flux controller at limit
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions: The specified flux setpoint cannot be achieved even though the maximum current has been provided.
Causes:
• Incorrect motor data (replacement circuit diagram data)
• Motor data and motor connection type (star/delta) do not match
• Motor has become unstable because motor data grossly wrong
• Current limit is too low for the motor (0.9 * MD 1238 * MD 1103 < MD 1136)• Power section too smallReactions:
– Mode group not ready.
– Channel not ready.
– Channel not ready.
– NC Start disable in this channel.