Sinumerik Alarm 300742 Axis %1 drive %2 voltage/frequency mode: converter frequency invalid
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
Only converter frequencies (MD 1100: $MD_PWM_FREQUENCY (pulse width modulation frequency)) of 4 kHz or 8 kHz are permissible in V/f mode (selected via MD 1014: $MD_UF_MODE_ENABLE).
Reactions:
– NC not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.
Remedy:
Please inform the authorized personnel/service department. Check and, if necessary, correct the torque adaptation factor MD 1100: $MD_PWM_FREQUENCY (pulse width mod- ulation frequency) or remedy the problem by deselecting V/f mode MD 1014: $MD_UF_MODE_ENABLE.
Program Continuation:
Switch control OFF – ON.
References
- Siemens Diagnostics Guide by Siemens