Sinumerik Alarm 301712 Axis %1 drive %2 multiturn SSI motor measuring system invalid


Sinumerik Alarm 301712 Axis %1 drive %2 multiturn SSI motor measuring system invalid

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
The configuration of a linear SSI motor measuring system is incorrect: A linear measuring system cannot have any multiturn information.

Reactions:
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– Alarm display.
– Interface signals are set.

Remedy:
Set MD_1021 $MD_ENC_ABS_TURNS_MOTOR (resolution number revolution) to 0.

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 301712 Axis %1 drive %2 multiturn SSI motor measuring system invalid