Sinumerik Alarm 301715 Axis %1 drive %2 multiturn SSI direct measuring system invalid


Sinumerik Alarm 301715 Axis %1 drive %2 multiturn SSI direct measuring system invalid

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
Configuration faulty for a linear and direct measuring system with SSI: A linear measuring system cannot have any multiturn information.

Reactions:
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– Alarm display.
– Interface signals are set.

Remedy:
Set MD_1031 $MD_ENC_ABS_TURNS_DIRECT (resolution number revolution) to 0.

Program Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 301715 Axis %1 drive %2 multiturn SSI direct measuring system invalid