Sinumerik Alarm 301715 Axis %1 drive %2 multiturn SSI direct measuring system invalid
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
Configuration faulty for a linear and direct measuring system with SSI: A linear measuring system cannot have any multiturn information.
Reactions:
– Mode group not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– Alarm display.
– Interface signals are set.
Remedy:
Set MD_1031 $MD_ENC_ABS_TURNS_DIRECT (resolution number revolution) to 0.
Program Continuation:
Switch control OFF – ON.
References
- Siemens Diagnostics Guide by Siemens