Sinumerik Alarm 310607 Axis %1 drive %2 valve not responding


Sinumerik Alarm 310607 Axis %1 drive %2 valve not responding

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
The valve is not responding to the valve slide setpoint. Cause: valve not connected or valve has no valve slide checkback signal.

Reactions:
– Mode group not ready.
– Channel not ready.
– Channel not ready.
– NC Start disable in this channel.
– NC Stop on alarm.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.

Remedy:
• Valve without valve slide checkback signal: Modify MD 5530: reset bit 2
• Check the valve connection.

Program Continuation:
Clear alarm with the RESET key in all channels of this mode group. Restart part program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 310607 Axis %1 drive %2 valve not responding