Sinumerik Alarm 310701 Axis %1 drive %2 speed controller cycle time invalid


Sinumerik Alarm 310701 Axis %1 drive %2 speed controller cycle time invalid

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
In the speed controller cycle drive MD 5001: SPEEDCTRL_CYCLE_TIME an impermissible value has been entered.

Reactions:
– NC not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.

Remedy:
Permissible: 62.5µs <= T <= 500µsProgram Continuation:
Switch control OFF – ON.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 310701 Axis %1 drive %2 speed controller cycle time invalid