Sinumerik Alarm 310755 Axis %1 drive %2 area factor too high


Sinumerik Alarm 310755 Axis %1 drive %2 area factor too high

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
The positive area factor in drive MD 5462 AREA_FACTOR_POS_OUTPUT is too high or the negative area factor in drive MD 5463 AREA_FACTOR_NEG_OUTPUT is too high.

Reactions:
– NC not ready.
– Channel not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.

Remedy:
Select a smaller value for the positive area factor in drive MD 5462 AREA_FACTOR_POS_OUTPUT or select a smaller value for the negative area factor in drive MD 5463 AREA_FACTOR_NEG_OUTPUT.

Program Continuation:
Clear alarm with the RESET key in all channels. Restart part program.