Sinumerik Alarm 310763 Axis %1 drive %2 D component of force controller invalid


Sinumerik Alarm 310763 Axis %1 drive %2 D component of force controller invalid

Parameters:
%1 = NC axis number
%2 = Drive number

Definitions:
The D component of the force controller MD 5246: FORCECTRL_DIFF_TIME is too high.

Reactions:
– NC not ready.
– Channel not ready.
– Channel not ready.
– NC Stop on alarm.
– NC Start disable in this channel.
– The NC switches to follow-up mode.
– Alarm display.
– Interface signals are set.

Remedy:
Enter a smaller value for the D component of the force controller MD 5246: FORCECTRL_DIFF_TIME.

Program Continuation:
Clear alarm with the RESET key in all channels. Restart part program.

References

  1. Siemens Diagnostics Guide by Siemens
Sinumerik Alarm 310763 Axis %1 drive %2 D component of force controller invalid